Chapter 4 Parameters
4-152
08-51 Material Thickness Unit: 0.001
Control
mode
VF VFPG SVC FOCPG TQCPG
Factory Setting: 1.000
Settings 0.001 to 60.000mm
It is used to set the thickness of the material.
08-52 Filter Time of Reel Diameter Unit: 0.01
Control
mode
VF VFPG SVC FOCPG TQCPG
Factory Setting: 1.00
Settings 0.00 to 100.00 sec
This parameter can be used to improve unstable of the source of reel diameter(Pr.08-42).
08-53 Auto Compensation of Reel Diameter
Control
mode
VF VFPG SVC FOCPG TQCPG
Factory Setting: 0
Settings 0 Disable
1 Enable
This parameter is only valid when Pr.08-21 is set to 1 and Pr.08-37 is not set to 0. It can
use this parameter for auto compensation of reel diameter when the mechanical gear
ratio or line speed can’t be accurate.
08-54 Current Reel Diameter Unit: 0.1
Control
mode
VF VFPG SVC FOCPG TQCPG
Factory Setting: 1.0
Settings 1.0 to 6000.0 mm
When the AC motor drive is not at STOP, this parameter is read-only.
08-55 Smart Start Function
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 0
Settings 0 Disable
1 Enable
2 In unwind mode, rewind in reverse direction
08-56 Switch Level for Smart Start and PID Function Unit: 1
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 15.0
Settings 0.0~100.0% (according to Pr.08-26)