Chapter 4 Parameters
4-171
PC or PLC command
Handling time
of the AC drive
Response Delay Time
Pr.09-09
Response Message
of the AC Drive
RS-485 BUS
09-10 Transmission Master Frequency Unit: 0.01
Control
mode
VF VFPG SVC FOCPG TQCPG
Factory Setting: 60.00
Settings 0.00 ~ 600.00 Hz
When Pr.00-20 is set to 1 (RS485 communication). The AC motor drive will save the last
frequency command into Pr.09-10 when abnormal turn-off or momentary power loss.
After re-power on, it will with the frequency set in Pr.09-10 if there is no new frequency
command.
09-11 Block Transfer 1 Unit: 1
09-12 Block Transfer 2 Unit: 1
09-13 Block Transfer 3 Unit: 1
09-14 Block Transfer 4 Unit: 1
09-15 Block Transfer 5 Unit: 1
09-16 Block Transfer 6 Unit: 1
09-17 Block Transfer 7 Unit: 1
09-18 Block Transfer 8 Unit: 1
09-19 Block Transfer 9 Unit: 1
09-20 Block Transfer 10 Unit: 1
Control
mode
VF VFPG SVC FOCPG TQCPG
Factory Setting: 0
Settings 0 to 65535
There is a group of block transfer parameter available in the AC motor drive (Pr.09-11 to
Pr.09-20). User can use them (Pr.09-11 to Pr.09-20) to save those parameters that you
want to read.
09-21 Multi-function Output Status
Control
mode
VF VFPG SVC FOCPG TQCPG
Factory Setting: Read-only
Settings 0 to 65535