Chapter 4 Parameters
4-179
position overshoot won’t occur but the pulses differential is determined by Pr.11-18
(APR Gain).
10-24
Deceleration Time for Internal Position/Waiting Time for
Switching Max. Frequency
Unit: 0.01/0.1
Control
mode
VFPG FOCPG
Factory Setting: 3.00/3.0
Settings 0.00 to 600.00 sec/0.0 to 6000.0 sec
When the multi-function input terminal is set to 35 (ON), this parameter setting will be
the deceleration time for internal position.
When the multi-function input terminal is set to 43 (ON), this parameter setting will be
the waiting time for switching the max. frequency.
10-00
10-01
RUN
MI=d35
MO=d39
10-19
10-24
output
frequency
PG
feedback
Time
10-25 Max. Frequency for Resolution Switch Unit: 0.01
Control
mode
VF VFPG SVC FOCPG TQCPG
Factory Setting: 50.00
Settings 0.00 to 600.00Hz
This function is used to enhance the function of unstable speed/position due to
insufficient resolution of analog simulation value. It needs to use with external input
terminals (one of Pr.02-01 to Pr.02-06/Pr.02-23 to Pr.02-30 should be set to 43). After
setting this parameter, it needs to adjust the analog output resolution of controller.