Chapter 4 Parameters
4-153
Example: Assume that the tension feedback 0~100% corresponds to loose tension to
tight tension, Pr.08-26=50% and Pr.08-56=10%, the smart start range will be from 0~40%.
08-57 Frequency for Smart Start Unit: 1
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 2.00
Settings 0.00~600.00Hz
08-58 Accel. Time for Smart Start Unit: 0.01
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 3.00
Settings 0.01~600.00 sec
Pr.08-55~08-58 are only valid when Pr.08-21 is set to 1.
Pr.08-58 is only valid when there is no source of line speed.
When start-up, it can set Pr.08-55 to 1 to prevent too long time for stable the dancer
(under loose material or out of Pr.08-56 setting).
Example: The PID control is only valid when setting Pr.08-57 and Pr.08-58 to make the
tension feedback reaches Pr.08-56 setting.
In unwind mode, when Pr.08-55 is set to 2, it allows to operate the motor in opposite
direction to tight the material automatically.
08-59 Broken Belt Detection
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 0
Settings 0 Disable
1 Enable
08-60 Min. Line Speed of Broken Belt Detection Unit: 0.1
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 0.0
Settings 0.0~3000.0 m/min
08-61 Allowance Difference of Reel Diameter of Broken Belt Detection Unit: 0.1
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 100.0
Settings 1.0~6000.0 mm