4-173
Group 10 PID Control
In this group, ASR is short for the Auto Speed Regulation and PG is short for Pulse Generator.
10-00 Encoder Pulse Unit: 1
Control
mode
VFPG FOCPG TQCPG
Factory Setting: 600
Settings 1 to 20000 (Max=20000 for 2-pole motor)
A Pulse Generator (PG) or encoder is used as a sensor that provides a feedback signal
of the motor speed. This parameter defines the number of pulses for each cycle of the
PG control.
10-01
Encoder Input Type Setting
Control
mode
VFPG FOCPG TQCPG
Factory Setting: 0
Settings 0 Disable
1
Phase A leads in a forward run command and phase B leads in a
reverse run command
A
B
FWD
REV
2
Phase B leads in a forward run command and phase A leads in a
reverse run command
A
B
FWD
REV
3
Phase A is a pulse input and phase B is a direction input. (low
input=reverse direction, high input=forward direction)
A
B
FWD
REV
4
Phase A is a pulse input and phase B is a direction input. (low
input=forward direction, high input=reverse direction)
A
B
FWD
REV
5
Single-phase input