Chapter 3 Digital Keypad Operation and Start Up
3-8 Revision Apr. 2016, 07VE, SW V2.05
Step 3 Trial run for FOCPG feedback control
Selection of speed
feedback card
E MV-P G01X
E MV-P G01O
E MV-P G01L
Encoder pulse
Pr.10-00
Encoder input type setting
Pr.10 -01
Pr.00-10=3
FOCPG control mode
If the motor can run
YES
NO
Stop trial run
Check if PG card
is nor mal
YES
NO
NO
YES
Check if output
current is normal
Refer to chapter 6
for fault c ode
Check the setting
of Pr.10-00
Change the operation
direction of motor
Increase the
frequency command
Finish trial run
If there is
mechanical
gear
YES
Check the setting of
gear ratio (Pr.10-27~
10-28)