Chapter 4 Parameters
4-15
Pr. Explanation Settings
F
actory
Setting
VF VFPG
SVC FOCPG
TQCPG
06-28
Electronic Thermal
Characteristic for Motor 2
30.0~600.0 sec 60.0
06-29
PTC (Positive
Temperature Coefficient)
Detection Selection
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
0
06-30
PTC Level 0.0~100.0% 50.0
06-31
Filter Time for PTC
Detection
0.00~10.00sec 0.20
06-32
Output Frequency for
Malfunction
0.00~655.35 Hz Read-
only
06-33
Output Voltage for
Malfunction
0.0~6553.5 V Read-
only
06-34
DC Voltage for
Malfunction
0.0~6553.5 V Read-
only
06-35
Output Current for
Malfunction
0.00~655.35 Amp Read-
only
06-36
IGBT Temperature for
Malfunction
0.0~6553.5 °C Read-
only