Loading...
system
Digi TransPort WR Routers User Guide
481
another device.
Value is either on or off. The default value is off.
description
A description of this device.
Accepted value is any string up to 255 characters.
wizard
Enables or disables the Getting Started Wizard. To skip the wizard, disable this option.
Value is either on or off. The default value is on.
ipsec-debug
Sets the IPsec debugging level in the ipsec.debug file. These messages can help diagnose issues with
IPsec configuration and interoperability.
Accepted value is any integer from -1 to 4. The default value is -1.
log-to-file
Enables or disables logging events to a file. If disabled, the log is created in RAM, and is lost when the
device is rebooted. If enabled, the log is created to flash and is saved on reboot. Saving event logs to
files and keeping them resident for some time is not recommended for normal operations, as this
practice can lead to additional wear to the device's flash memory.
Value is either on or off. The default value is off.
log-system-to-file
If enabled, log system/kernel events to system.log (on flash, will be saved on reboot). This is not
recommended for normal operations, as this practice can lead to additional wear to the device's flash
memory.
Value is either on or off. The default value is off.
timezone
Sets the system timezone. When the date and time is set using SNTP, the system time is set to
Universal Coordinated Time (UTC) and not to your local time. In addition, the date and time, whether
it is set manually or using SNTP, does not automatically change to reflect Daylight Saving Time (DST).
By setting the time zone, the device displays the local time for that time zone and automatically
adjusts for daylight saving time.
Accepted values can be one of none, canada-atlantic, canada-central, canada-eastern, canada-
mountain, canada-newfoundland, canada-pacific, europe-central, europe-eastern, europe-western,
uk-ireland, us-alaska, us-arizona, us-central, us-eastern, us-hawaii, us-mountain or us-pacific. The
default value is none.
log-to-syslog
Enables logging events to a syslog server
Accepted values can be multiple values of syslog1, syslog2 and off. The default value is off.
log-system-to-syslog
Enables logging system events to a syslog server