7. Optional: End the batch manually at any time before it reaches the target.
Option Description
Display Choose MenuBatcherRun BatchBatch Control and select End.
ProLink III Choose Device ToolsApplication ControlBatchingRun Batcher and
select End Batch.
Field communicator Not available
If you end a batch manually, you will not be able to resume it. You can end the batch while it is running
and while it is paused.
8. If you did not end the batch manually, wait until the batch ends automatically.
The batch ends automatically when it reaches the target or when it reaches the configured maximum
fill time.
9. Optional: Inhibit batch.
Option
Description
Display Not available
ProLink III Choose Device ToolsApplication ControlBatchingRun Batcher and set
Inhibit Batch Start to On or Off.
Field communicator Not available
While the Inhibit Batch input is active, a batch will not be allowed to start. Attempting to start a batch
while the batch is inhibited will cause the Start Not Okay alarm to be posted.
10. Optional: Inhibit totalizer.
Option
Description
Display Not available
ProLink III Choose Device ToolsApplication ControlBatchingRun Batcher and set
Inhibit Batch Totalizing to On or Off.
Field communicator Not available
When the Inhibit Totalizer input is active, the Batch Total will not increment. A timeout alarm will occur
if the Batch Total is inhibited beyond the max batch time. The batch inventory for the current preset will
not increment while Inhibit Totalizer is active.
11. Optional: Inhibit flow.
Option
Description
Display Not available
ProLink III Choose Device ToolsApplication ControlBatchingRun Batcher and set
Allow Batch End with Flow to On or Off.
Field communicator Not available
When the Inhibit Flow input is active, the batch will ignore the flow rate of the assigned flow source,
allowing a batch to end. The batch total will not increment when flow is inhibited.