Setup 133
{Dim. Dbl. Offset}
This allows you to set the address offset for dimmer doubling. The default for this is 20000, to
match the Net2 standard offset, including Sensor dimming software. For dimmer doubling over
Local DMX, this value should be set to 256.
{Create Virtual HSB}
{Create Virtual HSB} allows you to disable creation of virtual hue and saturation parameters.
This option is disabled by default.
When Virtual HSB controls are disabled, the hue and saturation columns will not display in Table
view. You will not be able to record just the Hue or Saturation values into a cue, submaster,
preset, or palette, and you cannot apply an effect to Hue and Saturation. You will still be able to
control Hue and Saturation from the encoders, ML Controls, Color Picker, and the command
line.
{Home Preset}
Allows you to specify a preset that will be used as the home level for all non-intensity
parameters in the preset, instead of the fixture library defaults. This preset will be applied for all
“Go to Cue Out” and home commands. Channels not included in the assigned home preset will
continue to home to their library defaults.
{System Startup Macro}
This field allows you to set up a startup macro that will trigger after the console initialization has
completed.
{System Shutdown Macro}
This field allows you to set up a disconnect macro that will trigger at power off, not when exiting
the application.
Cue Settings
Press {Cue Settings} to enter this category.
Two fields will be available to you: {Mark Time} and {Preheat Time}. You can also set cue
default times in this display.
To change the setting for any of these fields, press the field in the CIA to activate it. If the field
requires data, enter it from the keypad. If the field is a toggle state, one press of the button will
switch the field to its other state.
{Mark Time}
This field allows you to set the time that mark instructions will use. When {Mark Time} is
disabled, which is the default, mark instructions will use cue timing unless overridden with
discrete timing.
{Preheat Time}
If this option is disabled, the cues up intensity time will be used when preheating. The default
setting is “Disabled”.
Cue Default Times
This area allows you to set the default cue times for the parameter categories of your system. To
change a time, touch the parameter category button in the CIA and enter the desired time on
the keypad. To set a time for all categories at once, press {Selection Button} [Thru]. Pressing [At]
selects manual times.