Basic Manual Control 175
Address Check
Address check allows you to quickly step through all of your patched addresses.
Address check differs from
Address at Level (on the previous page)
because it skips non-intensity
parameters of patched addresses. Since address check follows the current flexichannel state, it
can be used with all channels to identify unpatched channels, or with flexi-patched to only show
the intensity addresses of patched channels.
[Dimmer/Address] [1] [At] [Full] {Check} [Enter] - brings address 1 to full intensity.
Use [Next] or [Last] to progress through the address list to complete the address check. Any key
press other than [Next] or [Last] will terminate address check mode.
Flash
Using the {Flash} softkey in Live will bring a channel or address to full, and then every other
second the level will move to 15%. That will hold for 1 second, and then the level will return to
full. The channel or address will keep flashing until either the command line is cleared, or
[Next]/[Last] is used to increment to the next channel or address.
[1]{Flash} - will bring channel 1 to full, then to 15%.
[Next] - channel 1 returns to its previous state and the intensity for channel 2 will flash.
[Dimmer/Address][1][0]{Flash} - will bring address 10 to full, then to 15%.
Flash On & Flash Off
Pressing [Shift] & [Full] together will put all the selected channels at full and “Flash On” will be
posted to the command line.
Pressing [Shift] & [Out] together will put all the selected channels to out and “Flash Off” will be
posted to the command line.
Releasing the keys will return the channels to their previous state.