438 Eos Family v2.9.0 Operations Manual
When you enable the internal clock only, it starts running immediately and triggers events
appropriate to the time.
When both internal and external clocks are enabled, the internal clock does not start running
until the first valid external time is received. After that, it will run whenever the external time
source is absent.
Loop Times
First and last times define the overall loop. Times can be set anywhere from 00:00:00:00 to
23:59:59:29. When external time is being received, your console ignores these times. However,
you should still set them to match whatever loop times the external clock is using. When using
internal timing, it is important to set the first and last times. These set the start and stop or loop
points of the sequence.
Internal Clock
You can set the internal clock at any time by selecting the event list (<Event List> [1] [/]),
pressing [Time], and entering a time.
To reset the internal clock, select the event list and press [Time] [Enter].
Programming a Time Code Event List
Open the show control display.
[Displays]><More SK>>{Show Control}
Create a new event list.
<Event> [1] [/] [Enter]
Define the type of input.
<Event> [1] [/] {Type} {MIDI} [Enter]
Define the source of input (this is the source ID number of the Gateway 1-32).
<Event> [1] [/] {Source} {1} [Enter]
Specify if internal and/or external timing is enabled.
<Event> [1] [/] {Internal} {External} [Enter]
Define the first time and last time for the event list (times are given as 00:00:00:00).
<Event> [1] [/] {FirstTime} [2] [0] [1] [5] [Enter]
<Event> [1] [/] {LastTime} [2] [0] [4] [5] [1] [5] [Enter]
Specify the number of frames per second (FPS) used by the timing source (24, 25, or 30).
<Event> [1] [/] {FrameRate} [2] [5] [Enter]
When working in Live, to show the Time Code times in the Cue List, go to the Cue List Display.
[Cue] [Cue]
Select the Cue List to be triggered.
[Cue] [1] [/]
Now associate the Event List to the Selected Cue List.
[Cue] [1] [/] {Execute} {Timecode} {1} [Enter]
Both the Event List and the Cue List are ready for events to be added. There are three ways that
events can be added into the Event List.