Show Control 501
<uint32: down time delay (ms)>
<uint32: focus time duration (ms)>
<uint32: focus time delay (ms)>
<uint32: color time duration (ms)>
<uint32: color time delay (ms)>
<uint32: beam time duration (ms)>
<uint32: beam time delay (ms)>
<bool: preheat>
<OSC Number: curve>
<uint32: rate>
<string: mark>
<string: block>
<string: assert>
<OSC Number: link> or <string: link> (string if links to a separate cue list)
<uint32: follow time (ms)>
<uint32: hang time (ms)>
<bool: all fade>
<uint32: loop>
<bool: solo>
<string: timecode>
<uint32: part count> (not including base cue, so zero for cues with no parts)
<notes>
<scene (text)>
<bool:scene end>
<cue part index>(-1 if not a part of a cue, the index otherwise)
Example:
/eos/out/get/cue/1/1/0/list/0/27 = 0, “00000000-0000-0000-0000-000000000000”,
“My Cue One Label, 0, 0, 0, 0, 0, 0, 6000, 0, 0, 0, True, 901, 90, “”, “B”, “A”, 3, 0,
0, True, 1, False, 00:00:00:02”, 0
CUE (2 OF 4):
/eos/out /get/cue/<cue list number>/<cue number>/<cue part number>/fx/list/<list index>/<list
count> =
<uint32: index>
<string: OSC UID>
<OSC Number Range: effect list>