FortiGate Version 3.0 MR4 Administration Guide
176 01-30004-0203-20070102
Chassis monitoring event log messages System Chassis (FortiGate-5000 series)
Chassis monitoring event log messages
FortiGate-5000 series modules can send the log messages shown in Table 31
when chassis monitoring detects temperatures, voltages, or fan speeds that are
outside of normal operating parameters. The messages in Table 31 all have the
chassis log type and a severity of warning or critical. Warning messages are
recorded when non-critical thresholds are reached. Critical messages are
recorded when critical thresholds are reached.
Table 31: Chassis monitoring warning and critical event log messages
ID Message Meaning
99503 Chassis fan anomaly: Fan
<fan_integer>, <rpm_integer>
RPM Chassis fan anomaly
A chassis fan is operating at an RPM value
outside of the normal operating range.
<fan_integer> is the number of the fan tray. For
the FortiGate-5140 <fan_integer> can be 0, 1, or
2. The FortiGate-5050 only has one fan tray.
<rpm_integer> is the RPM at which the fan is
operating.
99504 Chassis temperature anomaly:
T <sensor_integer>,
<temp_integer> Celsius
A temperature sensor has reported a
temperature outside of the normal operating
range for this sensor. A typical operating range is
between 10 and 75 degrees Celsius.
<temp_integer> identifies the temperature
sensor. <temp_integer> is the temperature being
reported by the sensor.
99505 Chassis voltage anomaly:
V<design_voltage>,
<monitored_voltage> V
A chassis voltage sensor has detected a voltage
level outside of the operating range for the
sensor. <design_voltage> is the voltage the
circuit should have at the sensor location during
normal operation. For example,
<design_voltage> could be 3.3, 5, and so on.
<monitored_voltage> is the actual voltage
measure by the sensor.
99506 Blade fan anomaly: Fan
<fan_integer>, <rpm_integer>
RPM
A blade fan is operating at an RPM value outside
of the normal operating range. <fan_integer>
identifies the fan. <rpm_integer> is the RPM at
which the fan is operating.
99507 Blade temperature anomaly:
Blade <temp_integer>,
<temp_integer> Celsius
A temperature sensor on a FortiGate-5000 or
FortiSwitch-5000 series module has reported a
temperature outside of the normal operating
range for this sensor. A typical operating range is
between 10 and 75 degrees Celsius.
<temp_integer> identifies the module
temperature sensor. <temp_integer> is the
temperature being reported by the sensor.
99508 Blade voltage anomaly: Blade
<design_voltage>,
<monitored_voltage> V
A voltage sensor on a FortiGate-5000 or
FortiSwitch-5000 series module has detected a
voltage level outside of the operating range for
the sensor. <design_voltage> is the voltage the
circuit should have at the sensor location during
normal operation. For example,
<design_voltage> could be 3.3, 5, and so on.
<monitored_voltage> is the actual voltage
measure by the sensor.