the Contact for Inquiries section if provided in Safety Precautions supplied with this product, and then make an
inquiry.
Memory Error/LSI Error
If a memory error or LSI error occurs, the following is displayed on the operator panel.
● For the LCD
An error code, error details, and a solution for the problem are displayed on the LCD.
Error Code Error Details and the Solution
C0:E5 C0:E5 Error
Memory error (Front)
Turn the power back on. If the problem persists, refer to the Operator's
Guide and take measures accordingly.
C0:E6 C0:E6 Error
Memory error (Back)
Turn the power back on. If the problem persists, refer to the Operator's
Guide and take measures accordingly.
C0:E9 C0:E9 Error
LSI error (Front)
Turn the power back on. If the problem persists, refer to the Operator's
Guide and take measures accordingly.
C0:EA C0:EA Error
LSI error (Back)
Turn the power back on. If the problem persists, refer to the Operator's
Guide and take measures accordingly.
C1:E0 C1:E0 Error
LSI error (Initialization failure)
Turn the power back on. If the problem persists, refer to the Operator's
Guide and take measures accordingly.
● For the Function Number Display
An alphabetical character and a number for the error code are displayed alternately on the Function Number
Display.
Error Code Error Details (displayed in the Error Recovery Guide window)
C0 Memory error (Front)
Memory error (Back)
LSI error (Front)
LSI error (Back)
C1 LSI error (Initialization failure)
Turn the scanner off then back on.
Troubleshooting
255