Field Description
The default value is Select one....
User name Enter the user name.
Password Enter the password.
Always Active Select whether the interface should always be activated.
The function is activated with Enabled.
The function is disabled by default.
Only activate this option if you have Internet access with a flat-
rate charge.
Connection Idle Timeout Only if Always on is disabled.
Enter the idle interval in seconds. This determines how many
seconds should pass between sending the last traffic data pack-
et and clearing the connection.
Possible values are 0 to 3600 (seconds). 0 deactivates the
timeout.
The default value is 300.
Example: 10 for FTP transmission, 20 for LAN-to-LAN transmis-
sion, 90 for Internet connections.
Fields in the PPTP IP Mode and Routes menu
Field Description
IP Address Mode Select whether your device is to be assigned a static IP address
or whether it should be assigned this dynamically.
Possible values:
• Get IP Address (default value): Your device is automatic-
ally assigned a temporarily valid IP address from the provider.
• Static: You enter a static IP address.
Default Route Select whether the route to this connection partner is to be
defined as the default route.
Funkwerk Enterprise Communications GmbH
13 WAN
bintec W1002/W1002n/W2002/WIx040/WIx065 217

Table of Contents

Other manuals for Funkwerk W1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Funkwerk W1002 and is the answer not in the manual?

Funkwerk W1002 Specifications

General IconGeneral
BrandFunkwerk
ModelW1002
CategoryWireless Access Point
LanguageEnglish

Related product manuals