Field Description
The first character in this field must not be a number and no
special characters or umlauts must be used either.
PPTP Mode Enter the role to be assigned to the PPTP interface.
Possible values:
• PNS (default value): this assigns the PPTP interface the role
of PPTP server.
• Windows Client Mode: this assigns the PPTP interface the
role of PPTP client.
User name Enter the user name.
Password Enter the password.
Always Active
Select whether the interface should always be activated.
The function is activated with Enabled.
The function is disabled by default.
Connection Idle Timeout
Only if Always up is disabled.
Enter the idle interval in seconds. This determines how many
seconds should pass between sending the last traffic data pack-
et and clearing the connection.
Possible values are 0 to 3600 (seconds). 0 deactivates the
timeout.
The default value is 300.
Example: 10 for FTP transmission, 20 for LAN-to-LAN transmis-
sion, 90 for Internet connections.
Remote PPTP IP Ad-
dress
Enter the IP address of the PPTP partner.
Fields in the PPTP Tunnel IP Mode and Routes menu
Field Description
IP Address Mode Select whether your device is to be assigned a static IP address
or whether it should be assigned this dynamically.
Possible values:
14 VPN Funkwerk Enterprise Communications GmbH
256 bintec W1002/W1002n/W2002/WIx040/WIx065