EasyManua.ls Logo

GE CARESCAPE ONE - About standby

GE CARESCAPE ONE
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Startingandendingmonitoring
withthecurrentpatient’sMRN:,SecondID:,andName:iftheyareavailable.Those
eldsareblankiftheinformationhasnotpreviouslybeenentered.
WhenCARESCAPEONEisusedasanacquisitionmodulewithahostmonitor,thehost
monitorContinuemenuprovidesoptionsforhandlingpatientdatathatmaybestored
intheCARESCAPEONE.Refertothehostmonitoruser’smanualformoreinformation.
TheContinuemenuremainsopenuntilyouselectoneoftheseoptions:
SelectContinueCurrenttocontinuemonitoringthecurrentpatientwiththe
settingsandpatientinformationinthemonitor.
SelectNewPatient(NewCaseinORandPACUsoftwarepackages)todischarge
thecurrentpatientfromthemonitor,deletingallpatientinformationandresetting
themonitortothedefaultvaluesforallsettings,includingalarmlimits.Youcan
thenadmitthenewpatienttothemonitor.
SelectStandbytoreturnthemonitortostandbymode.Thisoptiononlyappears
whenthemonitorhascomeoutofstandbymodeandthereisnopatient
connected.ItisnotpossibletoenterstandbymodeiftheCARESCAPEONEdetects
anyactiveparameterdata.
Aboutstandby
Whenyouremovethepatienttemporarilyfromthemonitor,youcanusethe
standbyoptiontoputthemonitoronstandbyuntilthepatientisreconnectedto
themonitor.Youcanalsousethestandbyoptionbeforeapatientisadmittedto
themonitor/patientcaseisstarted.Congurethecurrentpatientsettingsforthe
incomingpatient,thenputthemonitorinstandbytopreventnuisancealarmsor
automaticdischargeduetomonitorinactivity.
Startingstandby
1.SelectthepatientinformationareaonthescreenorselectPt.Data&Trends>
Admit/DischargeorStart/ResetCase.
2.SelecttheStandbytab.
3.Ifapatientisconnected,selectPrepareforStandbytopauseaudiblealarmsfor2
minutes.Thisallowstimetodisconnectpatientcables.
Ifnopatientisconnected(noCARESCAPEParametersareconnectedtothe
CARESCAPEONE),selectStandbyfromtheStandbytab,andthemonitorwill
immediatelyenterstandby.
4.DisconnectthepatientcablesandcheckthatNIBPAutoisturnedoff.
Ifpatientcablesarestillconnectedandthemonitorreceivesvitalsigns,a
messageindicatingthataudioalarmshavebeenpausedappears.
Ifyoudonotdisconnectthecablesandvitalsignsarestillpresentaftertheaudio
pausetimeexpires,thestandbyiscanceled.Youcanalsocancelthestandby
beforethetimerexpiresbyselectingCancelStandby.
Themonitorwillautomaticallyenterstandbywhenallcablesaredisconnected
andNIBPAutoisturnedoff.ThescreengoesblankandtheGElogowiththe
messageStandbyappears.
70CARESCAPEONE2094480-001
CARESCAPE ONE User Manual DRAFT 26 October 2017

Table of Contents

Other manuals for GE CARESCAPE ONE

Related product manuals