Operation - Sequential Blending Overview
Part No.: 4418309_Rev09 Fusion4 MSC-L
Honeywell Installation & Operation Manual 5 - 91
5.12 Sequential Blending Overview
Sequential blending is defined in chapter 3.1.3.4 "Sequential Blending".
This section describes how this functionality can be achieved using
MSC-L. Only product streams can be sequentially blended and share
common flow meter, temperature, pressure and density inputs and
control valve outputs. Each product shall be loaded one at a time and
hereafter be called a minibatch.
Stream board
missing
Ext. add. device program failure 0x0010
Option board
missing
Ext. add. device program failure 0x0010
Batch permissive
failure
Ext. add. device program failure 0x0010
Service due
reminder
Service due reminder 0x4000
Control failure Control fault 0x0400
No activity No activity 0x0020
Solenoid fault Solenoid fault 0x0080
Stream start fault Ext. add. device program failure 0x0010
Pulse phase error Pulse hardware error 0x1000
Pulse hardware
error
Pulse hardware error 0x1000
Leaking valve Leaking valve 0x0004
Flush volume Flush volume 0x0040
No pump No pump 0x0100
Block valve fault Solenoid fault 0x0080
Factored pulse
fault
Control fault 0x0400
No hydraulic pump No pump 0x0100
Tank low level Tank empty 0x2000
Tank empty Tank empty 0x2000
Low volume
deviation
Add. volume deviation 0x0001
High volume
deviation
Add. volume deviation 0x0001
No additive No additive 0x0002
General fail alarm/
any other alarm
not listed above
Ext. add. device firmware failure 0x0008