Operation - Calibration
Part No.: 4418309_Rev09 Fusion4 MSC-L
Honeywell Installation & Operation Manual 5 - 255
5.18.2 Calibration Menu Choice
1. On the Main Menu screen, select the Calibration icon to perform
the calibration process.
FIGURE 5-36 Calibration icon
2. On the Calibration screen, select either <Wizard> calibration method
or the <Manual> calibration method.
In the <Wizard> calibration method, the meter factor is calculated
by comparing the measured volume with the device dispensed
volume.
In the <Manual> calibration method, you must enter the meter
factor.
The default meter factor for the <Wizard> calibration method and the
<Manual> calibration method is 1. The range which can be specified
for the meter factor is between 0.5 and 1.5.