Operation - Stream Configuration
Fusion4 MSC-L Part No.: 4418309_Rev09
5 - 164 Installation & Operation Manual
Honeywell
NOTE: The pressure should be entered as a gauge
pressure.
5.14.1.5 Stream Config . Stream n . Alarms
On the Stream Config . Stream n screen, select <Alarms>.
[Thermal expansion coeff.]
With this entity you can enter the
expansion coefficient used during the
volume conversion. This is only
applicable for Special application
commodity group.
<Value>
<Units>
default = <0.00000E+00> 1/°C
[Density reading correction]
With this entity you can select if the
density reading correction should apply
to
[Observed density] parameter. Set
this parameter to
<D1298-12B> if
[Observed density] was entered as a
direct reading of glass hydrometer
complying with D1298-12B standard.
<None> (Default)
<D1298-12B>
[Mixture percentage]
With this entity you can enter the
product stream mixture percentage
(either by mass or by volume) as it is
measured in a lab.
Currently this is only relevant to
NBR15639-08 (Ethanol Mix)
commodity group, providing that
[Mixture calc. option] parameter set to
either
<Percentage (by mass)> or
<Percentage (by volume)>.
<0...100%>
<100%>
(Default)
[Mixture calc. option]
With this entity you can select the lab
observation data to be used for VCF
calculations for mixtures.
Currently this is only relevant to
NBR15639-08 (Ethanol Mix)
commodity group.
<Observed density> (Default)
<Percentage (by mass)>
<Percentage (by volume)>
Entity Range
[Observed density units] <Kilogram per Cubic Meter>
<Degrees API>
<Pounds per Cubic Feet>
<Relative Density at 60 F>
<Kilogram per liter>
[Observed temperature] <Degrees Celsius>
<Degrees Fahrenheit>
[Observed pressure] ->
<Units>
<Pascal>
<Kilo Pascal>
<Pounds per Square Inch>
<PSI large>
<Bar>
Entity Description Value range

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Fusion4 MSC-L and is the answer not in the manual?

Honeywell Fusion4 MSC-L Specifications

General IconGeneral
BrandHoneywell
ModelFusion4 MSC-L
CategoryDesktop
LanguageEnglish

Related product manuals