11-20
Port-Based Virtual LANs (VLANs) and GVRP
Port-Based Virtual LANs (Static VLANs)
Converting a Dynamic VLAN to a Static VLAN. If GVRP is running on
the switch and a port dynamically joins a VLAN, you can use the next
command to convert the dynamic VLAN to a static VLAN. (For GVRP and
dynamic VLAN operation, see “GVRP” on page 11-33.) This is necessary if you
want to make the VLAN permanent. After you convert a dynamic VLAN to
static, you must configure the switch’s per-port participation in the VLAN in
the same way that you would for any static VLAN.
Syntax: static-vlan <vlan-id>(Use show vlan to list current VIDs.)
For example, suppose a dynamic VLAN with a VID of 125 exists on the switch.
The following command converts the VLAN to a static VLAN.
HPswitch(config)# static-vlan 125
Configuring Static VLAN Name and Per-Port Settings. The vlan <vlan-
id> command, used with the options listed below, changes the name of an
existing static VLAN and changes the per-port VLAN membership settings.
Note You can use these options from the configuration level by beginning the
command with vlan <vlan-id>, or from the context level of the specific VLAN.
Syntax: name <vlan-name> Changes the name of the existing static
VLAN. (Avoid spaces and the following
characters in the <vlan-name> entry: 2, #,
$, ^, &, *, (, and ).)
[no] tagged <port-list> Configures the indicated port(s) as
Tagged for the specified VLAN. The
no” version sets the port(s) to
either No or (if GVRP is enabled) to Auto.
[no] untagged <port-list> Configures the indicated port(s) as
Untagged for the specified VLAN. The
no” version sets the port(s) to
either No or (if GVRP is enabled) to Auto.
[no] forbid <port-list> Configures the indicated port(s) as
“forbidden” to participate in the
designated VLAN. The “no” version sets
the port(s) to either No or (if GVRP is
enabled) to Auto.
auto <port-list> Available if GVRP is enabled on the
switch. Returns the per-port settings
for the specified VLAN to Auto
operation. Note that Auto is the default
per-port setting for a static VLAN if
GVRP is running on the switch.
(For information on dynamic VLAN and GVRP operation, see “GVRP” on page
11-33.)
!Software.book Page 20 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing