Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
2410 to 2411 UPS Test Failure UPSUNIT
SPNLCRD
2413 UPS Interface Failure UPSUNIT
SPNLCRD
2600 Power Good Fault PGDPART
TWRCARD
PWRSPLY
2601 to 2604 Power Good Fault PGDPART
TWRCARD
2610 Processor/Memory Card not installed PWRSPLY
TWRCARD
2612 Optical Converter 5V Fault
The SPCN detected a fault on the SPCN card optical converter 5V.
CBLALL
TWRCARD
2613 Configuration Requires 200V Input
Configuration now requires 200V AC power.
CBLALL
300E EPO Circuit Fault
The ac module installed in the 9406 Expansion Unit (FC 504x) detected a
fault in the UEPO signal. The signal was active and the incoming ac
voltage was still present.
TWRCARD
21F9362
21F5680
302B PCC Overcurrent
The power control compartment is causing an over current condition in the
9406 Expansion Unit power system.
Exchange the ac module and the SPCN port cable at the same time.
TWRCARD
21F5680
21F9631
21F9362
3100 I2C Bus Controller Communication fault I2CBUS
TWRCARD
3101 I2C Bus 1 Communication fault I2CBUS
TWRCARD
3102 I2C Bus 2 Communication fault I2CBUS
TWRCARD
3103 I2C Bus 3 Communication fault I2CBUS
TWRCARD
3104 I2C Bus 4 Communication fault I2CBUS
TWRCARD
3105 I2C Bus 5 Communication fault I2CBUS
TWRCARD
3106 I2C Bus 6 Communication fault I2CBUS
TWRCARD
3110 I2C Bus DASD Backplane 1 Communication fault I2CBUS
TWRCARD
3111 I2C Bus DASD Backplane 2 Communication fault I2CBUS
TWRCARD
3112 I2C Bus DASD Backplane 3 Communication fault I2CBUS
TWRCARD
3113 I2C Bus Adapter Communication fault I2CBUS
TWRCARD
1xxx
92