5. Are you finished with the repair?
No Yes
Replace the covers that were removed during this procedure and return
to the procedure that sent you here.
This ends the procedure.
6. To Install a disk unit using dedicated maintenance perform the following:
a. Power off the system (see Powering On and Powering Off the System and
Logical Partitions on page 922).
b. Disconnect the power cord.
c. Put the disk unit part way into the desired slot and rotate the handle of the
disk unit towards you.
d. Push the disk unit completely into the slot and rotate the handle towards
the disk unit to latch it into the slot.
e. Replace the covers that were removed during this procedure and return to
the procedure that sent you here.
This ends the procedure.
FC 5074, FC 5079 Control Panel NB1
Attention: The control panel is sensitive to electrostatic discharge (see
Appendix C. Working with Electrostatic Discharge-Sensitive Parts on page 955).
1. Power off the expansion tower. (See Powering On and Powering Off the
System and Logical Partitions on page 922.)
2. Disconnect the AC power cord from the expansion tower.
3. Open the front cover. (See FC 5074, FC 5079, FC 9079 Covers on page 623.)
4. Pull on the two side fasteners to release the control panel assembly.
Remove and Replace Procedures