b. Move the cursor to the HSL I/O Bridge resource and select the option
Display detail.
c. Examine the Leading port and Trailing port information. Search the display
for the HSL port location label that you previously recorded prior to
starting this procedure. If the HSL port location label that you came to this
procedure with is part of the information for the Leading port, then select
the function Follow leading port. Otherwise, if the HSL port location label
that you came to this procedure with is part of the information for the
Trailing port, then select the function Follow trailing port.
d. Perform the step below that matches the function you selected in the
previous step:
v If you selected the function Follow Leading Port in the previous step,
then examine the display for the Trailing port information. Record, on the
worksheet that you are using, the HSL port location label shown on the
Trailing port from previous resource line. Record this information as the
To HSL Port Label.
v If you selected the function Follow Trailing Port in the previous step,
then examine the display for the Leading port information. Record, on the
worksheet that you are using, the HSL port location label on the
Leading port to next resource line. Record this information as the To
HSL Port Label.
e. Record the Link type (Copper or Optical) on the worksheet that you are
using in the field describing the cable type.
f. Record the resource name on the display.
g. Select the Cancel function to return to the Logical Resources Associated
with a Packaging Resource display.
h. Select the Cancel function to return to the Packaging Resources Associated
with a Logical Resource display.
i. Select the Cancel function to return to the Logical Hardware Associated
With HSL Loops display.
j. Move the cursor to the resource with the resource name you recorded in
step 12f.
k. Select the Associated packaging resource(s)option.
l. Record the frame ID on the worksheet that you are using for the To Frame
ID.
m. Return to the procedure that sent you here.
This ends the procedure.
BUS PIP IOP-01, IOP Reset
This procedure will direct you to reset an IOP.
Attention: When the IOP reset is performed, all resources controlled by the IOP
will be reset. Perform the IOP reset only if the customer has verified that the IOP
reset can be performed at this time.
1. Go to the SST/DST screen in the partition which reported the problem. Use
STRSST if OS/400 is running, use function 21 if STRSST does not work, or IPL
the partition to DST.
2. On the Start Service Tools Sign On display, type in a User ID with QSRV
authority and Password.
3. Select the Start a service tool option.
4. Select the Hardware service manager option.
Bus, High-Speed Link (HSL) PIPs