Code
Description/Action Perform all actions before exchanging
Failing Items
Failing Item Location
7777 Hardware configuration change detected
A hardware resource is missing. The resource reported in to the
system on a previous IPL, but has not reported in on the
current IPL. This could occur for several different reasons.
1. It could be a normal situation where the resource is
currently powered off. In this case, when the resource is
powered back on, it will no longer be missing.
2. The hardware resource could also be missing if it has been
removed from the system, for example, a tape drive that
was replaced with a different tape drive. The service
representative should use the Hardware service manager to
remove the entry for this resource.
3. The resource may not have reported in on this IPL because
it is failing. Perform problem analysis to determine why the
resource is failing.
CFFC Optical library device condition not expected
The optical disk drive addressing within the optical library is
incorrect. This error is likely to be the result of faulty cabling or
switch setting following service to an optical library.
Contact your hardware service provider.
OPTLCBL
DRVSWCH
CFFD Optical drive failure OPTLDRV
CFFF Media determined to be bad in Optical library
F103 Main storage dump must be copied for service.
Perform LIC-PIP1 on page 342.
FDC0 LIC program reported informational error
This reference code is logged for information only. No action
required.
FDC5 LIC program failed and data was captured
This reference code indicates first failure data capture (FFDC)
data was collected for a problem reported by licensed internal
code.
The user should dial IBM Software Support for assistance.
GG3FFDC
Licensed Internal Code (LIC) Failing Items
Failing Item Description Document Description
21H7625 Incorrect, defective or missing SCSI jumper card Repair and Parts; removal and installation
procedures
AJDG301 Licensed Internal Code Service Functions; APAR or LICTR
AJDGP01 Service processor Licensed Internal Code Repair and Parts; removal and installation
procedures
AJGLD01 I/O card Licensed Internal Code Service Functions; APAR or LICTR
BACKPLN Card enclosure or backplane Problem Analysis; Symbolic FRU Isolation
BSTWRPL I/O tower card Problem Analysis; Symbolic FRU Isolation
B6xx (including A6xx)
274
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1