Install the original I/O card by doing the following:
a. Power off the system or the expansion tower (see Powering On and
Powering Off the System and Logical Partitions on page 922).
b. Remove the I/O card you installed in step 8 of this procedure and install
the original I/O card.
Note: Do not power on the system or the expansion tower now.
A device connected to the I/O card could be the failing item.
Go to SDIOP-PIP16, step 7 on page 408 to continue isolating the problem.
This ends the procedure.
SDIOP-PIP16
Introduction: This procedure isolates failing devices that are identified by FI
codes FI01105, FI01106, and FI01107. In this procedure, you will remove devices
that are identified by the FI code. Then you will perform an IPL to determine if the
symptoms of the failure have disappeared, or changed. You should not remove the
load-source disk until you have shown that the other devices are not failing.
Removing the load-source disk can change the symptom of failure, although it is
not the failing unit.
Note: If the system has logical partitions, perform this procedure from the logical
partition that reported the problem. See iSeries Service Functions for more
information on logical partitions.
1. Perform an IPL to DST (see Dedicated Service Tools (DST) in the iSeries
Service Functions information).
Does an SRC appear on the control panel?
No Yes
Go to step 6 of this procedure.
2. Does one of the following displays appear on the console?
v Disk Configuration Error Report
v Disk Configuration Warning Report
v Display Unknown Mirrored Load-Source Status
v Display Load-Source Failure
Note: On the Disk Configuration Error Report display, the characters under
Type are the same as the 4 leftmost characters of word 1. The characters
under Reference Code are the same as the 4 rightmost characters of word
1.
Yes No
Go to step 5 of this procedure.
3. On some of the displays that are listed in step 2 of this procedure, you must
press F11 to display reference codes.
Are all of the reference codes 0000?
No Yes
Go to LIC-PIP 11 on page 350 and use cause code 0002.
This ends the procedure.
SDIOP PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 407