Model 830 and SB2 System Processor Failing Items
Failing Item Description Document Description
AJDG301 Licensed Internal Code error Service Functions; APAR or LICTR
AJDGP01 Service processor Licensed Internal Code Service Functions; APAR or LICTR
ANYMEM System Sub-Card(s) Problem Analysis; Symbolic FRU Isolation
ANYMEMX System Sub-Card(s) Problem Analysis; Symbolic FRU Isolation
ANYPROC System Card(s) or BackPlane Problem Analysis; Symbolic FRU Isolation
CCIN System Sub-Card(s) Problem Analysis; Symbolic FRU Isolation
CCIN System Card(s) or BackPlane Problem Analysis; Symbolic FRU Isolation
CTLPNCD System Sub-Card(s) Problem Analysis; Symbolic FRU Isolation
MUMIOCD Bus expansion card Problem Analysis; Symbolic FRU Isolation
NEXTLVL Call your next level of support for assistance Problem Analysis; Symbolic FRU Isolation
NOMSUSE Main storage failure Problem Analysis; Symbolic FRU Isolation
RIOPORT System bus error Problem Analysis; Symbolic FRU Isolation
(B467) System Processor Reference Codes
The system processor detected a failure.
Collect data from Functions 11, 12, and 13 of the system panel, or words 1 through
9 from the Main Store Dump (MSD) screen. This SRC, beginning with B4, may
contain up to five FRUs. Eight characters of this data represent a single FRU. The
FRU characters have two parts: a unit reference code, and a type number. The
location of this data is shown below:
PANEL FUNC 11: B4xx____ RC01TP01
RC02RC03 RC04RC05
PANEL FUNC 12: DATA0012 DATA0013
TP02TP03 TP04TP05
PANEL FUNC 13: DATA0016 DATA0017
DATA0018 DATA0019
The FRU information for FRU 1 would be RC01 and TP01, for FRU 2 would be
RC02 and TP02, etc.
Characters Description / Meaning Length
RC01 FRU 1 - Ref Code 4 Characters
TP01 FRU 1 - Type 4 Characters
RC02 FRU 2 - Ref Code 4 Characters
TP02 FRU 2 - Type 4 Characters
RC03, TP03, RC04, TP04, RC05, TP05 same as above.
DATA012, DATA013,
DATA016, DATA017,
DATA018, DATA019
Miscellaneous Data - Not applicable, but
may be needed for your next level of
support.
8 Characters
The example below shows relevant data for three FRUs:
RC01=5200, TP01=245E, RC02=8100, TP02=3197, RC03=9300, TP03=25AA,
the remaining values are zeroes.
B437
Chapter 2. Unit Reference Codes 229