LBUSADP
The failing item is the HSL I/O bridge Card in a FC 5033, FC 5034, FC 5035 or FC
5077 SPD migrated tower.
Go to symbolic FRU LBUSADP in the Migrated Expansion Tower Problem Analysis,
Repair and Parts for information on servicing this failing item.
This ends the procedure.
LOC_SYS
A problem has occurred on the local (this) system with HSL OptiConnect. The
Service Action Log (SAL) code will attempt to identify the HSL loop number as a
portion of the part description for this symbolic FRU. Search the SAL of this
system for hardware and LIC problems. Correct any problems that you find with
LIC or Network Interface Controller (NIC) hardware.
This ends the procedure.
LPARCFG
There is a configuration problem with a logical partition. Perform any actions
listed in the ″Description/Action″ column in the Unit Reference Code Table for the
SRC.
Have the customer check processor and memory allocations to the secondary
partitions. The customer must ensure there are enough functioning processor and
memory resources in the system for all the partitions. Be aware that processor or
memory resources that failed during system IPL could have caused the IPL
problem in the secondary partition.
Have the customer check the bus and I/O processor allocations for the secondary
partition. The customer must ensure that the partition has load source and console
I/O resources.
Have the customer check the IPL mode of the Primary partition and the failing
secondary partition:
v If the Primary partition is IPL’d in mode ’C’ then secondary partitions can only
be IPL’d in mode ’C’. If that is the problem, then re-IPL the Primary partition in
either ’A’ or ’B’ mode. Then the secondary partition can IPL in any mode.
v If the Primary partition is IPL’d in mode ’C’ then ″Guest″ partitions will not IPL.
For ″Guest″ partitions, this may be a problem accessing or loading the specified
Kernel.
For further assistance the customer should contact their software service provider,
or visit the IBM web page at http://www.as400.ibm.com/lpar for additional
support direction.
This ends the procedure.
LPARSUP
There is either an IPL problem, MSD problem, or a software error with a secondary
partition. Perform any actions listed in the ″Description/Action″ column in the
Unit Reference Code Table for the SRC.
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 551