EasyManuals Logo
Home>IBM>Server>i 830

IBM i 830 User Manual

IBM i 830
1000 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #358 background imageLoading...
Page #358 background image
Yes No
Provide the dumps to IBM Service Support.
This ends the procedure.
22. Use the new SRC and go to Chapter 2. Unit Reference Codes on page 59.
This ends the procedure.
LIC-PIP3
Note: Determine if the system has logical partitions. Go to Determining if the
System Has Logical Partitions on page 943, before continuing with this
procedure.
Note: If the system has logical partitions, perform this procedure from the logical
partition that reported the problem.
Dedicated service tools (DST) found a permanent program error, or a hardware
failure occurred.
Read the Overview on page 341 before continuing with this procedure.
1. Does URC 50FF occur?
No Yes
Go to step 3 of this procedure.
2. Perform a main storage dump, then perform an IPL by doing the following:
a. Perform a main storage dump (see Perform a Main Storage Dump to Disk
in the iSeries Service Functions information).
b. Select manual mode and perform an IPL to DST (see Dedicated Service
Tools (DST) in the iSeries Service Functions information).
c. When the IPL has completed, the system console should be at the DST
display. If the DST display does not appear on the system console, go to
BUS-PIP1 on page 285. Otherwise, go to step 6 of this procedure.
3. Perform a main storage dump, then perform an IPL by doing the following:
a. Perform a main storage dump (see Perform a Main Storage Dump to Disk
in the iSeries Service Functions information).
b. Select manual mode and perform an IPL to DST (see Dedicated Service
Tools (DST) in the iSeries Service Functions information).
Does a display appear?
No Yes
Go to step 6 of this procedure.
4. If the problem is in the Primary partition, exchange the first workstation I/O
processor card on bus 1 (see Chapter 4. Removal and Installation Procedures
on page 617). If the problem is in the secondary partition, exchange the I/O
processor card for the console of the secondary partition. To locate a secondary
partitions console and workstation I/O processor, see the iSeries Service
Functions.
5. Select manual mode and perform an IPL to DST (see Dedicated Service Tools
(DST) in the iSeries Service Functions information).
Is the IPL or Install the System display shown?
Yes No
LIC PIPs
344
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish