BUS PIP HSL-06
BUS PIP HSL-06, Use HSM to examine the HSL Loop to determine if other systems
are connected to the loop.
1. Sign on to SST or DST (if you have not already done so).
2. Select Start a service tool.
3. Select Hardware service manager.
4. Select Logical hardware resources.
5. Select High-speed link (HSL) resources.
6. Move the cursor to the HSL loop that you are here to examine. Select the
Display detail option.
7. Search for Remote HSL NIC(s) on the loop.
Is there any Remote HSL NIC(s) on the loop?
No Yes
You have determined that there are other systems connected to this
loop.
This ends the procedure.
8. You have determined that there are not any other systems connected to this
loop.
This ends the procedure.
Bus PIP HSL-07
Starting with a frame ID, for a frame connected to an HSL loop, this procedure will
determine if there is another frame with the same frame ID on the loop. This is
possible when more than one system is connected to an HSL loop.
1. Sign on to SST or to DST if you have not already done so.
2. Select Start a Service Tool.
3. Select Hardware Service Manager.
4. Select Logical Hardware Resources.
5. Select High Speed Link (HSL) Resources.
6. Move the cursor to the HSL loop that you are here to examine. Select the
Resources associated with loop option.
7. Select the function Include non-reporting resources.
8. The display that appears is showing the loop resource and all the HSL I/O
Bridge and all the Remote HSL NIC resources connected to the loop.
9. Perform the following for each HSL I/O Bridge resource on the display:
a. Move the cursor to the HSL I/O Bridge resource and select the Associated
packaging resource(s) option.
b. Compare the frame ID on the display with the frame ID (in hexadecimal
format) that you are looking to find (Ignore leading zeros).
c. Are the frame IDs the same?
No Yes
Record the resource name and the Type-Model of the HSL I/O
Bridge with the frame ID for possible use later. Select the Display
Detail option and record the SPCN system serial number. The
SPCN system serial number is the serial number of the system unit
that controls the power subsystem on the frame (it connects to the
frame with an SPCN cable). Select the Cancel function to the
Bus, High-Speed Link (HSL) PIPs