This ends the procedure.
Exchanging a Disk Unit with Device Parity Protection
1. Does the failing unit have data parity protection that allows service without
possible data loss (see Determining Storage Protection Status on page 894)?
Yes No
Customer data may be lost if serviced. Ask your next level of support
for assistance.
This ends the procedure.
2. Record the disk unit location for later use. If you do not already have the disk
unit location information, use the location information in the Service Action
Log if it is available. If the location is not available, find the address. See SRC
Address Formats on page 936. Use the address to find the location. See
Locations and Addresses on page 705.
Exchange the failing disk unit (See Chapter 4. Removal and Installation
Procedures on page 617 for the model or FC that you are working on and
perform Disk Unit - Concurrent ). When finished, continue with the next step
of this procedure.
Note: If the concurrent procedure fails, go to step 5 of this procedure.
3. Perform the following:
a. Select System Service Tools (SST).
If you cannot get to SST, select dedicated service tool (DST) (see Accessing
Dedicated Service Tools in the iSeries Service Functions).
Note: Do not IPL the system to get to DST.
b. Select the Work with disk units option on the Service Tools display.
c. Select the Work with disk unit recovery option on the Work with Disk Units
display.
d. Select the Rebuild disk unit data option.
Does the disk unit you just exchanged appear on the display as a unit that can
be rebuilt?
Yes No
It can take up to 5 minutes for the input-output processor (IOP) to
report the device to the system. Keep trying the Rebuild Disk Unit Data
option until the device is available. If the Rebuild Disk Unit Data
Failed screen continues to appear even after 5 minutes, try a different
disk unit or ask your next level of support for assistance.
4. Perform the following:
a. Select the disk unit on the display that was installed in place of the failing
disk unit.
b. Rebuild the disk unit data. When the new disk unit is rebuilt, the display
shows that the status is complete (this may take 30 minutes or longer).
Note: Once the rebuild has started, it is not necessary to wait to verify the
array rebuild completes successfully.
c. Return to the procedure that sent you here.
This ends the procedure.
Data Recovery and General System Information
896
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals