Ask your next level of support for assistance. Characters 13-16 of the top 16
character line of function 12 (4 rightmost characters of word 3) contain information
regarding the install error. For more information about the install error, see the
“LIC Install Debug Information” chapter in the iSeries Licensed Internal Code
Diagnostic Aids - Volume 1. If the customer does not require the service displays to
be in the national language, you may be able to continue by doing another system
IPL.
This ends the procedure.
0099: A Licensed Internal Code program error occurred.
Ask your next level of support for assistance.
This ends the procedure.
LIC-PIP 12
This procedure isolates an IASP (Independent Auxiliary Storage Pool) vary on
failure. Message CPDB8E0 occurred if the user attempted to vary on the IASP.
Note: Determine if the system has logical partitions. Go to “Determining if the
System Has Logical Partitions” on page 943, before continuing with this
procedure.
Note: If the system has logical partitions, perform this procedure from the logical
partition that reported the problem.
Read the “Overview” on page 341 before continuing with this procedure.
How to Find the Cause Code:
1. Were you given a cause code by another procedure?
No Yes
↓ Use the cause code given by the other procedure.
Go to step 3 of this procedure.
2. Look at the characters in word 3. You can obtain these characters by doing the
following:
a. On the command line, enter STRSST (the Start System Service Tools)
command. If you cannot get to SST, use function 21 to get to DST (see
″Accessing Dedicated Service Tools″ in the iSeries Service Functions). Do not
IPL the system to get to DST.
b. On the Start Service Tools Sign On display, type in a User ID with QSRV
authority and Password.
c. Select Start a Service Tool.
d. On the Start a Service Tool display, select the Hardware Service Manager option
(see the iSeries Service Functions).
e. Select the Work with service action log option on the Hardware Service Manager
display.
f. On the Select Timeframe display, change the From: Date and Time to a date
and time prior to when the user attempted to vary on the IASP.
g. Search for a B6005094 system reference code that occurred at the time the
user attempted to vary on the IASP. Display the failing item information for
this entry.
LIC PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 363