DANGER
To prevent a possible electrical shock from touching two surfaces with
different electrical grounds, use one hand, when possible, to connect or
disconnect signal cables. (RSFTD004)
DANGER
To prevent a possible electrical shock during an electrical storm, do not
connect or disconnect cables or station protectors for communications lines,
display stations, printers, or telephones. (RSFTD003)
DANGER
To prevent power from switching on automatically during service procedures,
select manual or secure mode on the system unit control panel or disconnect
the cables that connect to J15 and J16 on the frame being serviced.
(RSFTD211)
Attention: When removing or installing the service processor card, failure to follow
the procedures in Chapter 4. Removal and Installation Procedures on page 617
may damage the card, the card enclosure, or both.
Read and understand the following service procedures before using this section:
v Powering On and Powering Off the System and Logical Partitions on page 922.
v The card procedure in Chapter 4. Removal and Installation Procedures on
page 617.
v Hardware Service Manager in the iSeries Service Functions information.
SP-PIP42
This procedure is for IPL failures that terminate very early in the IPL. This error
path is indicated when the SRC data words scrolling automatically through control
panel functions 11, 12 and 13 and the control panel user interface buttons are not
responsive.
If the control panel is NOT scrolling through the functions 11, 12 and 13 and the
control panel user interface DOES work, then go to INT-PIP24 Service Processor
Data Collection on page 340 instead of this procedure.
1. Record all of the SRC data words and describe the operation that was being
attempted.
2. Attempt a recovery by selecting the white button on the control panel to IPL.
Note: (The IPL mode will automatically change to attempt the recovery IPL
using a different IPL mode.)
Does the control panel show the function 01 display ?
Yes No
a. Attempt the white button IPL a second time.
b. If the failure still occurs, reload the service processor code. Contact
your next level of support to get instructions to reload the service
processor code.
Service Processor PIPs
438
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals