Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
90F0 A frame was dropped from the SPCN configuration.
A frame was dropped from the SPCN configuration. This is usually caused
by a loss of ac power or a problem with the frame-to-frame cable.
TWRCARD
CBLALL
90F1 A frame was added to the SPCN configuration.
No action required. This reference code is logged for information only.
9100 Battery capacity test completed.
No action required. This reference code is logged for information only.
9101 VLIC-SPCN Timeout
A Licensed Internal Code timeout occurred. The SPCN failed to respond to
a Licensed Internal Code command.
TWRCARD
CTLPNL
SVCPROC
9102 Assign Permanent Address command failure
A node failed to perform an Assign Permanent Address command.
TWRCARD
9103 Download Initialize Timeout
An SPCN node failed to enter the download state after an Initialize for
Download command.
Exchange the failing SPCN node.
TWRCARD
9104 Download Completion Timeout
An SPCN node failed to leave the download state.
Exchange the failing SPCN node.
TWRCARD
9105 Load Damaged Timeout
An SPCN node failed to enter the operational state.
Exchange the failing SPCN node.
TWRCARD
9106 An SPCN LID was not found.
No action required. This reference code is logged for information only.
9107 An SPCN microcode download is required.
No action required. This reference code is logged for error analysis only.
9108 A status change occured in one of the SPCN nodes.
No action required. This reference code is logged for information only.
9109 Licensed Internal Code part number is not correct.
The AROS part number field was not updated to the correct level after the
system attempted to load new Licensed Internal Code.
TWRCARD
9110 Battery Power Unit capacity test failed.
The battery power unit was not able to pass the capacity test.
BATRY
9111 SPCN is too large for VLIC.
There are more nodes in the network than VLIC can service.
AJDG301
9112 Primary SPCN node is reporting load damaged.
The Licensed Internal Code for the primary SPCN node is damaged. The
reload failed because the code could not be found.
TWRCARD
1xxx
110
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1