Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
9288 Configuration Error
A configuration error was detected during System Frame processing.
TWRCARD
AJDG301
9289 Invalid Packet Length for data sent.
Invalid Packet Length occurred for data exchanged.
AJDG301
TWRCARD
A100 Battery Power Unit capacity test failure
The battery power unit capacity test time exceeds the installed battery
capacity. The battery power may not be enough to provide a controlled
stop during a loss of incoming ac voltage.
This reference code is logged for information only.
A201 A Battery Power Unit 1 Failed
Battery power unit 1 capacity test failed.
BATRY
BATCHGR
A202 Battery Power Unit 2 Failed
Battery power unit 2 capacity test failed.
BATRY
BATCHGR
A300 Battery Power Unit missing
The existing number of battery power units installed may not be adequate
for the current configuration. If the battery power units are installed, insure
that they are properly connected before replacing any FRUs.
BATCHGR
BATRY
A301 A Battery Power Unit 1 Failed
The installed SPCN Licensed Internal Code does not give support to the
type of battery power unit installed. Install the latest SPCN code.
AJDG301
BATCHGR
A302 Battery Power Unit 2 Failed
The installed SPCN Licensed Internal Code does not give support to the
type of battery power unit installed. Install the latest SPCN code.
AJDG301
BATCHGR
AC01 to AC02 Internal Battery Power Unit Charger Fault BATCHGR
BKSPCN
B101 A Battery Power Unit 1 Failed
Battery power unit reported an over current condition on the +29 V dc bus.
PWRREG
BATCHGR
BACKPLN
B102 Battery Power Unit 2 Failed
Battery power unit 2 reported an over current condition on the +29 V dc
bus.
PWRREG
BATCHGR
BACKPLN
B201 A Battery Power Unit 1 Failed
Battery power unit 1 reported an over current condition on the +31 V dc
bus.
PWRREG
BATCHGR
BACKPLN
B202 Battery Power Unit 2 Failed
Battery power unit 2 reported an over current condition on the +31 V dc
bus.
PWRREG
BATCHGR
BACKPLN
C510 A Battery Power Unit 1 Failed
SPCN-to-battery power unit 1 or 3 communications fault occurred.
BATCHGR
ACMODUL
BACKPLN
C511 Battery Power Unit 2 Failed
SPCN-to-battery power unit 2 communications fault occurred.
BATCHGR
ACMODUL
BACKPLN
1xxx
Chapter 2. Unit Reference Codes 113