Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
3100 Tape/CD or disk bus interface error occurred
Perform “DU-PIP3” on page 328.
FI01112
DISKDRV
FI01106
DISKTRY
FI01141
FI01140
BACKPLN
DEVTERM
3109 IOP timed out a disk command DISKDRV
FI01112
FI01106
DISKTRY
FI01141
FI01140
BACKPLN
DEVTERM
3110 Disk bus interface error occurred
Perform “DU-PIP3” on page 328.
FI01112
DISKDRV
FI01106
DISKTRY
FI01141
FI01140
BACKPLN
DEVTERM
3130 Device Licensed Internal Code
The device is not supported with the level of code currently on the system.
Contact your next level of support.
SVCDOCS
7000 Disk sector read error
No action required. This reference code is logged for information only.
DISKDRV
7001 Temporary disk data error
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see “Hardware Service Manager” in the iSeries Service
Functions.
DISKDRV
7003 Device format error
If the disk has not been formatted by the system, initialize and format the
disk. See “Work with disk unit recovery” in the iSeries Service Functions.
7004 System log entry only, no service action required
7050 Data compression failure
Contact your next level of support.
SVCDOCS
7051 Compressed device and compression IOA are not compatible
The customer should perform the “Recovering From 6xxx7051 SRC”
procedure in the Backup and Recovery, SC41-5304-05.
CMPRES1
7052 Data compression warning
The customer should perform the “Recovering From 6xxx7052 SRC”
procedure in the Backup and Recovery, SC41-5304-05.
SVCDOCS
FFF2 Disk motor problem DISKDRV
FFF3 Disk media format bad DISKDRV
432x, 660x, 671x, 673x
152