Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
C100 SCSI bus command error occurred FI00870
FI01106
FI01112
MMVMEDA
FI01140
FI01141
DEVTERM
CDTRAY
C110 SCSI command timeout occurred FI00870
FI01106
FI01112
MMVMEDA
FI01140
FI01141
DEVTERM
CDTRAY
C210 Unexpected device condition recovered
The device successfully recovered from a temporary error.
No action is required. This reference code is logged for information only.
C300 Media or device error occurred
Perform the following:
1. Clean the disk.
2. Attempt the failing operation again.
3. If this does not correct the problem, exchange the failing items.
MMVMEDA
FI00870
C333 Incompatible media was detected
Perform the following:
1. Verify that the disk has a format that is given support.
2. If the format is given support, clean the disk and attempt the failing
operation again.
3. If the operation fails again with the same reference code, ask your
media source for a replacement disk.
MMVMEDA
FI00870
C400 Interface error detected by device FI00870
FI01106
FI01112
FI01140
FI01141
DEVTERM
CDTRAY
C402 I/O processor internal program error occurred
Ask your next level of support for assistance.
FI00130
CFF2 Recovered from device not ready - Start Unit issued
The device successfully recovered from a temporary error.
No action is required. This reference code is logged for information only.
CFF4 Internal device error occurred FI00870
632x, 6330
Chapter 2. Unit Reference Codes 155