Reference
Code
Description/Action Perform all actions before exchanging
Failing Items
Failing Item
9302 Tape device failure or media error
The tape unit detected a failure that may be caused by a
hardware failure or a media error.
Refer to the tape unit service information for possible
information on diagnostic tests that can be run to isolate
between hardware and media failures.
MLYTMED
86G9251
9310 Licensed Internal Code for the tape unit is not correct 86G9251
FI00130
9320 Tape device Licensed Internal Code failure FI00130
86G9251
9350 Tape unit detected a read or write error on tape medium
A permanent read or write error occured. Clean the tape
unit and retry the operation.
If cleaning the tape unit does not correct the problem,
exchange the tape media.
MLYTMED
86G9251
9351 Tape with excessive error rate was mounted in tape
device.
The tape unit detected that the mounted tape cartridge has
a history of excessive read and write errors. It is
recommended that you exchange the tape cartridge.
MLYTMED
ULYCLN
86G9251
9355 The data format is incorrect; the tape cannot be read
The tape unit has detected that the data format on the
tape media is not supported.
Clean the tape unit and retry the operation.
If the operation continues to fail, use a different tape
cartridge.
ULYUSR1
MLYTMED
ULYCLN
86G9251
9500 I/O processor Licensed Internal Code error
If the system is operational, take a dump of the I/O
processor data. For more infomration, see the iSeries Service
Functions information or ask your next level of support for
assistance.
FI00130
9600 Equipment Check Failure on Library Device.
See library device service information to resolve the error.
LIBDEV
9800 to 9803 I/O processor successfully recovered from temporary error
No action required. This reference code is logged for
information only.
9810 Problem analysis has determined a part should be
replaced.
This reference code is used for ending Online Problem
Analysis with a list of failing items. (Information only)
9427
176
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1