Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0103 WS IOP detected parity error from device
Is the problem intermittent?
No Yes
Perform the following procedures:
1. INT-PIP5 External Noise on Twinaxial Cables on page 333
2. INT-PIP14 Station Protectors on page 339
Perform TWSC-PIP1 on page 465.
FI00602
FI00601
GAU7777
FI00610
0104 Device detected parity error from WS IOP
Is the problem intermittent?
No Yes
Perform the following procedures:
1. INT-PIP5 External Noise on Twinaxial Cables on page 333
2. INT-PIP14 Station Protectors on page 339
Perform TWSC-PIP1 on page 465.
FI00602
FI00601
GAU7777
FI00610
0105 WS IOP detected error when transmitting data
Is the problem intermittent?
No Yes
Perform the following procedures:
1. INT-PIP5 External Noise on Twinaxial Cables on page 333
2. INT-PIP14 Station Protectors on page 339
Perform TWSC-PIP1 on page 465.
FI00602
FI00601
GAU8888
FI00610
FI00615
0106 WS IOP detected wrong data from device
Is the problem intermittent?
No Yes
Perform the following procedures:
1. INT-PIP5 External Noise on Twinaxial Cables on page 333
2. INT-PIP14 Station Protectors on page 339
Perform TWSC-PIP1 on page 465.
FI00601
FI00602
GAU8888
FI00610
0107 WS IOP detected wrong address from device
Is the problem intermittent?
No Yes
Perform the following procedures:
1. INT-PIP5 External Noise on Twinaxial Cables on page 333
2. INT-PIP14 Station Protectors on page 339
Perform TWSC-PIP1 on page 465.
FI00601
GAU8888
GAU7777
FI00610
0108 WS IOP detected device power turned off, and then on
Perform TWSC-PIP1 on page 465.
GAUEEEE
FI00601
B070