Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0183 WS IOP detected wrong display size value
Perform “TWSC-PIP1” on page 465.
FI00601
0184 WS IOP detected wrong keyboard identification
Verify that the correct keyboard is attached correctly to the workstation.
If the correct keyboard is attached correctly to the workstation, perform
“TWSC-PIP1” on page 465.
FI00601
0189 Wrong magnetic stripe reader or light pen status
Perform “TWSC-PIP1” on page 465.
FI00601
FI00605
FI00607
FI00610
0190 WS IOP detected no status change from device
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. “INT-PIP5 External Noise on Twinaxial Cables” on page 333
2. “INT-PIP14 Station Protectors” on page 339
Perform “TWSC-PIP1” on page 465.
FI00601
FI00610
GAU7777
0191 WS IOP detected busy time-out from device
Perform “TWSC-PIP1” on page 465.
FI00601
FI00610
0200 Device no response time-out; temporary error FI00604
FI00602
FI00610
0201 WS IOP detected error when transmitting data
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. “INT-PIP5 External Noise on Twinaxial Cables” on page 333
2. “INT-PIP14 Station Protectors” on page 339
Perform “TWSC-PIP1” on page 465.
FI00602
FI00604
GAU7777
GAU8888
FI00610
FI00615
0203 WS IOP detected parity error from device
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. “INT-PIP5 External Noise on Twinaxial Cables” on page 333
2. “INT-PIP14 Station Protectors” on page 339
Perform “TWSC-PIP1” on page 465.
FI00602
FI00604
GAU7777
FI00610
B070