Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0221 Device detected not valid value from WS IOP FI00604
AJLYD01
FI00610
0222 Device detected storage or data overrun FI00604
AJLYD01
FI00610
0223 WS IOP detected start command to printer was lost FI00604
FI00602
FI00610
0224 Device detected wrong start command from WS IOP FI00604
AJLYD01
FI00610
0225 WS IOP detected wrong exception response from device FI00604
FI00610
0230 to 0239, 0240
to 0248
Printer detected equipment error FI00604
0249 WS IOP detected wrong request or response from device FI00604
FI00610
0290 WS IOP detected no status change from device FI00604
FI00610
0291 WS IOP detected busy time-out from device FI00604
FI00610
A000 Too many devices active on the workstation IOP
This error occurs if you attempted to activate more workstations than
allowed.
Switch off power to (or remove) one or more of the display stations (except
for the console) that are attached to this workstation I/O processor.
Perform an initial program load (IPL) from the control panel to correct the
problem.
Refer to the local workstation diagrams for the location of workstations if
necessary.
GAUBBBB
B000 WS IOP fails to report part, model and serial number
Perform “TWSC-PIP1” on page 465.
FI00610
C000 WS IOP error not known AJLYD01
FI00610
D000 Work Station IOA start-up test error FI00610
D010 WS IOP storage failure corrected
Perform “TWSC-PIP1” on page 465.
FI00610
D011 WS IOP card storage failure FI00610
D021 WS IOP detected errors on all cables FI00602
FI00601
FI00610
FI00615
D022 WS IOP parity errors detected on all cables FI00602
FI00601
FI00610
FI00615
B070
Chapter 2. Unit Reference Codes 201