Code
Description/Action Perform all actions before exchanging
Failing Items
Failing Item Location
5350 Secondary partition software release not supported.
The logical partition software version is outside the supported
release delta. Check the Release Delta from the Primary
partition Display Partition Release Level screen.
Check the LPAR documentation for the release level of the
Primary partition and determine what the supported Release
Delta is.
5380 System LIC program exception occurred
Record the Procduct Activity Log (PAL) hex data for this SRC
or print the PAL entry.
Contact your next level of support.
LPARSUP
5390 System LIC program exception occurred
Record the Product Actvity Log (PAL) hex data for this SRC or
print the PAL entry.
Contact your next level of support.
LPARSUP
5555 SLIC I/O DASD subsystem error recovery in progress.
6900 System bus error
The copper bus, bus 4 in the SPD migrated tower, is
inoperative due to a stuck line or a parity error. Any SPD
system bus-related hardware on bus 4 may have failed
including the HSL I/O bridge or HSL cable connecting SPD bus
4 to the HSL loop.
Perform BUS-PIP1 on page 285.
FI00065
AJDG301
6901 Bus Expansion Adapter card failed
The copper bus, the first SPD bus in the system unit or
migrated tower, has failed due to an internal chip error on the
local bus adapter.
Perform BUS-PIP1 on page 285.
For this reference code the failing item list presented in the
Service Action Log can be different from the failing item list
documented here. That is due to the differences in system
models and features installed.
If the Service Action Log is available then use the failing item
list presented there for servicing this reference code.
If the Service Action Log is not available then use the failing
item list documented here. By following the procedures in the
symbolic FRUs listed here you will isolate to the correct FRU
list based on system model and features installed.
LBUSADP
AJDG301
6902 Bus Expansion Adapter card failed
An optical bus has failed due to an internal chip error on one
of the remote bus adapters.
Perform BUS-PIP1 on page 285.
FI00203
AJDG301
B6xx (including A6xx)
Chapter 2. Unit Reference Codes 253