Description/Action Perform all actions before exchanging
Failing Items
Failing Item Location
6908 High Speed Link (HSL) I/O bridge failure
LIC data in the I/O bus vpd could not be accessed. The I/O
Bus identified in the SRC may not have become operational.
For this reference code the failing item list presented in the
″Service Action Log″ can be different from the failing item list
documented here. That is due to the differences in system
models and features installed.
If the ″Service Action Log″ is available then use the failing item
list presented there for servicing this reference code.
If the ″Service Action Log″ is not available then use the failing
item list documented here. By following the procedures in the
symbolic FRUs listed here you will isolate to the correct FRU
list based on system model and features installed.
NOTE: A fiber optic cleaning kit may be required for optical
HSL connections.
SIIOADP
OPT_CLN
6909 High Speed Link (HSL) I/O bridge failure
LIC detected invalid data in the I/O bus VPD. The bus and
resources associated with it may not be operational.
For this reference code the failing item list presented in the
″Service Action Log″ can be different from the failing item list
documented here. That is due to the differences in system
models and features installed.
If the ″Service Action Log″ is available then use the failing item
list presented there for servicing this reference code.
If the ″Service Action Log″ is not available then use the failing
item list documented here. By following the procedures in the
symbolic FRUs listed here you will isolate to the correct FRU
list based on system model and features installed.
NOTE: A fiber optic cleaning kit may be required for optical
HSL connections.
SIIOADP
OPT_CLN
6910 I/O processor failure
An I/O processor timed out, returned bad status, or is not
following the system bus protocol.
Perform “LIC-PIP7” on page 345.
FI00310
FI00318
FI00065
FI00130
AJDG301
6938 Not valid system configuration detected
This system model does not allow a configuration of more than
three (non-OptiConnect) I/O Processors.
Power down the system and remove the extra
(non-OptiConnect) I/O Processor(s) so that there are three or
less. Restart the system.