Reference
Code
Description/Action Perform all actions before exchanging
Failing Items
Failing Item Location
6967 Multi-adapter bridge configuration change or error
I/O adapter unavailable due to moved I/O processor card.
The I/O adapter specified in word 7 of the SRC is not
available. On the previous IPL there was an I/O processor card
the adapter was assigend to. The I/O processor was not
detected on this IPL.
See the MABRCFG symbolic FRU for the list of messages, a
further description of the problem detected by Licensed
Internal Code and the corrective action.
MABRCFG
6968 Multi-adapter bridge configuration change or error
IOA removed from multi-adapter bridge slot.
On the previous IPL an I/O adapter was in the card slot
specified in word 7 of the SRC. That I/O adapter was not
detected on this IPL.
See the MABRCFG symbolic FRU for the list of messages, a
further description of the problem detected by Licensed
Internal Code and the corrective action.
MABRCFG
6969 Multi-adapter bridge configuration change or error
I/O adapter replaced by I/O processor card.
On the previous IPL there was an I/O adapter in the location
specified in word 7 of the SRC. This IPL LIC detected that the
IOA was replaced by an IOP in that location.
See the MABRCFG symbolic FRU for the list of messages, a
further description of the problem detected by Licensed
Internal Code and the corrective action.
MABRCFG
B6xx (including A6xx)
258
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1