v Serial/parallel port test.
Does the IOA/IOP test(s) complete successfully?
No Yes
The IOA/IOP is good. Do NOT replace the IOA/IOP. Go to step 5 of
this procedure.
4. The problem is in the IOA or IOP.
If a verify test identified a failing memory module, replace the memory
module.
On multiple card combinations, exchange the IOA card before exchanging the
IOP card.
Exchange the failing hardware (see Chapter 4. Removal and Installation
Procedures on page 617).
This ends the procedure.
5. Before running tests on modems or network equipment, the remaining local
hardware should be verified. Since the IOA/IOP test(s) have completed
successfully, the remaining local hardware to be tested is the external cable.
Is the IOA adapter type 2838, with a UTP (unshielded twisted pair) external
cable?
Yes No
Go to step 9 of this procedure.
6. Is the RJ-45 connector on the external cable correctly wired according to the
EIA/TIA-568A standard? i.e.
-Pins 1 and 2 using the same twisted pair,
-Pins 3 and 6 using the same twisted pair,
-Pins 4 and 5 using the same twisted pair,
-Pins 7 and 8 using the same twisted pair.
Yes No
Replace external cable with correctly wired cable.
This ends the procedure.
7. Do the Line Speed and Duplex values of the line description (DSPLINETH)
match the corresponding values for the network device (router, hub or switch)
port?
No Yes
Go to step 10 on page 328 of this procedure.
8. Change the Line Speed and/or Duplex value for either the line description or
the network device (router, hub or switch) port.
This ends the procedure.
9. Is the cable wrap test option available as a Verify test option for the hardware
you are testing?
Yes No
Go to step 11 on page 328 of this procedure.
Verify the external cable by running the cable wrap test.
Note: A wrap plug is required to perform the cable wrap test. This wrap plug
is available from IBM or your Hardware Service Provider.
Communications PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 327

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals