12. Record the SRC on the Problem Summary Form (see Appendix A. Problem
Summary Form on page 951).
Is the SRC the same one that sent you to this procedure?
No Yes
The last device you disconnected is not the failing item.
a. Leave the device disconnected and go to step 7 of this procedure
to continue isolation.
b. If you have disconnected all devices that are identified by FI code
FI01106 except the load-source disk unit, reconnect all devices.
Then go to step 16 of this procedure.
13. Does the Disk Configuration Error Report display or the Disk Configuration
Warning Report display appear on the console with one of the following
listed?
v Missing disk units in the configuration
v Missing mirror protection disk units in the configuration
v Device parity protected units in exposed mode.
Yes No
Go to step 13 of this procedure.
14. Select option 5 then press F11, then press the Enter key to display details.
Are all the reference codes 0000?
No Yes
The last device you disconnected is the failing item.
a. Reconnect all devices except the failing item.
b. Before exchanging a disk unit, go to Disk Unit in Chapter 4.
Removal and Installation Procedures on page 617.
This ends the procedure.
15. Use the reference code to correct the problem.
This ends the procedure.
16. Was disk unit 1 (the load-source disk unit) a failing item that FI code FI01106
identified?
Yes No
The failing items that FI code FI01106 identified are not failing. Use
the original SRC and exchange the failing items, starting with the
highest probable cause of failure (see the failing item list for this
reference code in Chapter 2. Unit Reference Codes on page 59). If the
failing item list contains FI codes, see Failing Items on page 479 to
help determine part numbers and location in the system.
This ends the procedure.
17. The failing items that FI code FI01106 identified are not failing. The
load-source disk unit may be failing. Use the original SRC and exchange the
failing items, starting with the highest probable cause of failure (see the failing
item list for this reference code in Chapter 2. Unit Reference Codes on
page 59). If the failing item list contains FI codes, see Failing Items on
page 479 to help determine part numbers and location in the system.
This ends the procedure.
Disk Unit PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 331

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals