c. Wait for the dump to disk to complete (this may take several minutes).
Is 0000 0000 displayed on the control panel for more than 30 seconds?
No Yes
The Main Store Dump cannot complete successfully. The Load Source
IOP is in a hang condition.
Go to step 6 of this procedure.
4. Does the Main Store Dump complete successfully (A1xx 300x displayed)?
Yes No
Go to step 7 of this procedure.
5. Work with the customer and your next level of support to collect the Main
Store Dump and APAR information. See:
v The Information Center at http://www.ibm.com/eserver/iseries/infocenter
a. Record the SRC information available in the Main Store Dump Summary.
b. Copy the main storage dump to media (see iSeries Service Functions).
Copy the main storage dump to removable media or disk. Copying to disk
is faster than copying to most types of tape devices. To successfully copy
to disk, you must have enough space available in auxiliary storage to hold
the main storage dump.
c. Go to step 7 of this procedure.
6. Perform an Load Source IOP dump (see iSeries Service Functions, Performing
an IOP Storage Dump to Disk). Select Function 70 on the control panel and
press the Enter key.
7. Perform the following:
a. Power off the system.
b. Power on the system in Manual mode.
Does the system IPL complete to DST?
No Yes
Go to Using the Service Action Log on page 9.
This ends the procedure.
8. Does the system stop with a reference code displayed on the control panel?
No Yes
Go to Chapter 2. Unit Reference Codes on page 59 and use the SRC
information to correct the problem.
This ends the procedure.
9. Did a Missing Disk Units display appear?
No Yes
Go to Using the Service Action Log on page 9.
This ends the procedure.
10. Did the Main Store Dump Manager display appear?
No Yes
Record the SRC information available in the Main Store Dump
Summary (see iSeries Service Functions).
IPL Problems
Chapter 1. Starting Problem Analysis 33

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals