This ends the procedure.
2. Is the alternate installation device ready?
Yes No
↓ Make the alternate installation device ready and retry the alternate
installation.
This ends the procedure.
3. Is there installation media in the alternate installation device?
Yes No
↓ Load the correct media and retry the alternate installation.
This ends the procedure.
4. Is the alternate installation device an external device?
Yes No
↓ Go to step 11 of this procedure.
5. Is the alternate installation device powered on?
Yes No
↓ Go to step 8 of this procedure.
6. Make sure that the alternate installation device is properly connected to the
I/O processor or I/O Adapter card.
Is the alternate installation device properly connected?
Yes No
↓ Correct the problem and retry the alternate installation.
This ends the procedure.
7. Go to step 11 of this procedure.
8. Ensure that the power cable is connected tightly to the power cable connector
at the back of the alternate device. Ensure that the power cable is connected to
a power outlet that has the correct voltage. Set the alternate device Power
switch to the Power On position.
The Power light should go on and remain on. If a power problem is present,
one of the following power failure conditions may occur:
v The Power light flashes, then remains off.
v The Power light does not go on.
v Another indication of a power problem occurs.
Does one of the above power failure conditions occur?
No Yes
↓ Perform the following:
a. Go to the service information for the specific alternate device to
correct the power problem.
b. When you have corrected the power problem, retry the alternate
installation.
This ends the procedure.
9. The alternate device is powered on and runs its power-on self-test. Wait for
the power-on self-test to complete.
Tape Unit PIPs
460