Failing Item Code
Description/Action If only a type number is listed, go to the “Type, Model, and Part
Number list” on page 885 to determine the part number.
FI00203 FI00203 indicates that the remote SPD optical bus receiver card in the expansion tower is
the failing item.
Use the receiver card type in the expansion tower to determine the part.
FI00204 FI00204 indicates that the bus cable between the migrated tower and the expansion tower is
the failing item.
FI00205 FI00205 indicates that the remote SPD optical bus receiver on the paired bus is the failing
item.
Use the receiver card type in the expansion tower bus to determine the part.
FI00206 FI00206 indicates that a type 2685 remote SPD optical bus receiver is the failing item.
Perform Bus PIP 1 in Migrated Expansion Tower Problem Analysis, Repair and Parts to
determine the failing item.
FI00230 FI00230 indicates that the Licensed Internal Code for the failing node is the failing item and
needs to be restored.
Determine the type of node and select the Licensed Internal Code load.
Primary node
AJSFDJ04
Secondary node
AJSFDJ05
FI00235 FI00235 indicates that an SPCN cable that connects two frames or a frame to a node is the
failing item. This FI is applicable only if a SPCN cable is installed.
The following list shows the lengths and part numbers of the possible failing items:
v 6.0 meters—part 21F9469
v 15.0 meters—part 21F9358
v 30.0 meters—part 21F9359
v 60.0 meters—part 21F9360
v 100.0 meters (SPCN optical cable)—part 21F9415
v SPCN optical adapter—part 90H6287
v SPCN port cable (frame-to-node)—part 21F9362
v Frame-to-frame cable—part 87G6235
v SPCN optical adapter —part 90H6287
FI00236 This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
FI00237 This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
FI00238 This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
FI00239 This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
Failing Items
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 483